GV Shaker Specification

  • Features
  • Variable speed control, Digital timer, Corrosion-resistant body
  • Temperature Resistance
  • Ambient to 60C
  • Accuracy
  • 2 RPM
  • Power Supply
  • Electric
  • Control Type
  • Digital
  • Speed Range
  • 50 To 250 RPM
  • Display Type
  • LED Digital Display
  • Shape
  • Rectangular
  • Type
  • Shaker
  • Dimension (L*W*H)
  • 560 x 470 x 275 mm
  • Equipment Type
  • Laboratory Shaker
  • Equipment Materials
  • Mild Steel Powder Coated
  • Power
  • 220V AC, 50 Hz
  • Voltage
  • 220 Volt (v)
  • Material
  • Mild Steel
  • Application
  • Mixing, agitating, dissolving substances in laboratory applications
  • Capacity (Ltr)
  • 3.6 Litres
 

GV Shaker Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 1 Unit Per Day
  • Delivery Time
  • 1 Days
 

About GV Shaker

Backed by a team of experienced personnel, we are engaged in providing GV Shaker. This mechanical and motorized testing machine is useful in stimulation of carbon dioxide, which is present in the test specimen. The test sample is placed in carbonation assembly and is placed on bottle shaker. Moreover, this instrument is also equipped with an adjustable bottle shaker for evading bottle slippage during the shaking process. Therefore, a GV Shaker is very useful in PET and preform industry. Further, it accommodates bottles of standard sizes easily, and can also be operated without much hustle. 

Product Details:

Cycle

Starting by pressing a single button auto stop on completion of cycle

Stroke Length

100 mm

Shaking Method

Linear Reciprocating

Safety

Emergency Button provided to stop system

Power

230 V / Single Phase / 0.25 hp /0.18 kW

Number of strokes / Min

0-100




Efficient Laboratory Mixing, Simplified

Designed with precision, the GV Shaker offers reliable performance for mixing, agitating, and dissolving tasks. Its controlled orbital motion ensures uniform sample treatment, enhancing experimental outcomes. The durable, powder-coated steel body protects the equipment from corrosion, making it suitable for demanding lab environments. The digital controls and clear LED display grant users easy, accurate adjustments for every procedure.


Versatility for Diverse Laboratory Needs

With its adjustable speed and timer, the GV Shaker meets the varying demands of laboratories across research, pharmaceutical, and industrial sectors. The unit supports both continuous and timed operations, allowing flexibility for different sample requirements. Overload protection and a quiet operation level enhance user safety and comfort during high-volume or extended processes.

FAQs of GV Shaker:


Q: How do I operate the GV Shaker for continuous and timed mixing?

A: The GV Shaker offers two operation modes: continuous for ongoing procedures and timed mode using the digital timer (0-99 minutes). Set your preferred mode and adjust the speed using the digital controls. The LED display ensures you can monitor and modify settings easily during operation.

Q: What are the main applications of the GV Shaker in laboratory environments?

A: This shaker is designed for mixing, agitating, and dissolving substances across chemistry, biology, and pharmaceutical labs. Common uses include sample preparation, reagent mixing, and cell culture agitation, making it suitable for research, quality control, and educational settings.

Q: When should I use the variable speed control feature?

A: Variable speed adjustment (50 to 250 RPM) is ideal for tailoring agitation intensity to specific sample needs. Use lower speeds for gentle mixing of sensitive samples and higher speeds for thorough dissolution or more robust agitation processes.

Q: Where can the GV Shaker be safely placed and used?

A: The shaker is compact and can be placed on any stable, level laboratory bench. Its corrosion-resistant, powder-coated mild steel body ensures longevity, even in environments with occasional chemical exposure. Always ensure proper ventilation and check for secure platform placement before use.

Q: What steps are involved in safely operating the GV Shaker?

A: To operate safely, place samples securely on the 350 x 350 mm platform, ensure the load does not exceed 6 kg, set your speed and timer using the digital controls, and monitor progress via the LED display. The overload protection feature automatically halts operation if excessive load or resistance is detected, preventing equipment damage.

Q: What benefits does the GV Shaker offer over traditional manual mixing methods?

A: The GV Shaker delivers homogenized, reproducible results quickly and efficiently, reducing manual effort and risk of inconsistency. Its accurate digital control, quiet operation, and built-in safety mechanisms greatly enhance both workflow and laboratory safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email